For the PRI set, the system automatically creates a serial interface numbered serial interface-numbe:15 .
This interface is logically equivalent to an ISDN PRI interface where you can make other configurations
such as:
DCC
PPP and PPP authentication
IP addressing
Backup center settings if the interface is to be used as a primary or secondary interface for backup
Firewall
Configuring other CE1/PRI interface parameters
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter CE1/PRI interface view.
controller e1 number N/A
3. Configure the interface
description.
description text
By default, the description of an
interface is interface-name
Interface.
4. Set the line code format.
code { ami | hdb3 }
The default is high density bipolar
3 (HDB3).
5. Set the cable type.
cable { long | short }
The default cable setting is long
mode.
6. Set the clock mode.
clock { master | slave }
The default clock mode is slave,
which is line clock.
7. Enable automatic clock mode
change.
clock-change auto
By default, automatic clock mode
change is disabled.
8. Set the line idle code type.
idlecode { 7e | ff } The default is 0x7E.
9. Set the type of interframe
filling tag.
itf type { 7e | ff } The default is 0x7E.
10. Set the number of interframe
filling tags.
itf number number The default is 4.
11. Set the loopback mode.
loopback { local | payload |
remote }
By default, loopback is disabled.
12. Enable user data inversion.
data-coding { inverted | normal }
By default, user data inversion is
disabled.
13. Restore the default settings for
the CE1/PRI interface.
default Optional.
14. Bring up the CE1/PRI
interface.
undo shutdown
By default, a CE1/PRI interface is
up.
15. Return to system view.
quit N/A
16. Enter the view of the
synchronous serial interface
created on the CE1/PRI
interface.
interface serial
interface-number:set-number
or
interface serial
interface-number:15
N/A