R0106-HP MSR Router Series Interface Command Reference(V7)
147
BERT state: (stopped, not completed)
E3 2/4/0 CE1 14: up
Frame-format: NO-CRC4, clock: slave, loopback: not set
Receiver alarm state: none
BERT state: (stopped, not completed)
E3 2/4/0 CE1 15: up
Frame-format: NO-CRC4, clock: slave, loopback: not set
Receiver alarm state: none
BERT state: (stopped, not completed)
E3 2/4/0 CE1 16: up
Frame-format: NO-CRC4, clock: slave, loopback: not set
Receiver alarm state: none
BERT state: (stopped, not completed)
Table 17 Command output
Field Descri
p
tion
E3 2/4/0
Current state
Physical state of the interface: up or down.
Description Description about the E3 interface.
Frame-format
Frame format configured on the E3 interface: CRC4 or
NO CRC4.
Line Code Line code: AMI or B8ZS.
clock
Source clock used by the interface: master for the
internal clock or slave for the line clock.
National-bit International bit.
Current mode Operating mode of the E3 interface: E3 or CE3.
Loopback Loopback setting on the interface.
Alarm Alarm state.
BERT state
BERT state: completed, stopped (not completed), or
running.
Test pattern Test pattern in use: 2^20 or 2^15.
Status Whether the interface is being synchronized.
Sync Detected Number of detected synchronizations.
Time Duration of the BERT test.
Time past Time that has elapsed.
Bit Errors (since test started)
Number of bit errors received since the start of the
BERT test.
Bits Received (since test started) Number of bits received since the start of the BERT test.
Bit Errors (since latest sync)
Number of bit errors received since the last
synchronization.
Bits Received (since latest sync)
Number of bits received since the last
synchronization.
E3 2/4/0 CE1 1 Physical state of the E1 channel: up or down.