R0106-HP MSR Router Series Layer 2 - LAN Switching Configuration Guide(V7)
81
Configuring loop detection
Overview
Incorrect network connections or configurations can create Layer 2 loops, which results in repeated
transmission of broadcasts, multicasts, or unknown unicasts. The repeated transmission can waste
network resources and can sometimes paralyze networks. The loop detection mechanism immediately
generates a log when a loop occurs so that you are promptly notified to adjust network connections and
configurations. You can configure loop detection to shut down the looped port. Logs are maintained in
the information center. For more information, see Network Management and Monitoring Configuration
Guide.
Loop detection mechanism
The router detects loops by sending detection frames and then checking whether these frames return to
any port on the router. If they do, the router considers that the port is on a looped link.
Loop detection usually works within a VLAN. If a detection frame is returned with a different VLAN tag
than it was sent out with, an inter-VLAN loop has occurred. To remove the loop, examine the QinQ
configuration for incorrect settings. For more information about QinQ, see "Configuring QinQ."
Figure 23 Ethernet frame header for loop detection
The Ethernet frame header for loop detection contains the following fields:
• DMAC—Destination MAC address of the frame, which is the multicast MAC address
010F-E200-0007. When a loop detection-enabled router receives a frame with this destination
MAC address, it sends the frame to the CPU and floods the frame in the VLAN from which the frame
was originally received.
• SMAC—Source MAC address of the frame, which is the bridge MAC address of the sending router.
• TPID—Type of the VLAN tag, with the value of 0x8100.
• TCI—Information of the VLAN tag, including the priority and VLAN ID.
• Type—Protocol type, with the value of 0x8918.
Figure 24 Inner frame header for loop detection