R0106-HP MSR Router Series Layer 2 - WAN Command Reference(V7)
230
Table 49 CNS directive description
Directive Descri
p
tion
CNSn
Controls the CNS heartbeat debugging switch.
• n = 00000500000000000000—Enables CNS heartbeat debugging.
• n = 00000800000000000000—Disables CNS heartbeat debugging.
Usage guidelines
The sendat command does not verify the configuration directive. Each time it issues one configuration
directive to the 3G/4G modem, lowercase characters are automatically converted to uppercase
characters..
Configuration directives might cause malfunction of a 3G/4G modem. When you issue a configuration
directive to the modem, make sure you understand the impact on the 3G/4G modem.
Examples
# Issue the ATD169 directive to the 3G/4G modem to call number 169.
<Sysname> system-view
[Sysname] controller cellular 2/0/0
[Sysname-Cellular2/0/0] sendat ATD169
# Issue the cns00000500000000000000 directive to the 3G/4G modem to enable CNS heartbeat
debugging.
<Sysname> system-view
[Sysname] controller cellular 2/0/0
[Sysname-Cellular2/0/0] sendat cns00000500000000000000
shutdown
Use shutdown to shut down a cellular interface.
Use undo shutdown to bring up a cellular interface.
Syntax
shutdown
undo shutdown
Default
The cellular interface is up.
Views
Cellular interface view
Predefined user roles
network-admin
Examples
# Shut down Cellular 2/0/0.
<Sysname> system-view
[Sysname] interface cellular 2/0/0
[Sysname-Cellular2/0/0] shutdown