R0106-HP MSR Router Series Network Management and Monitoring Command Reference(V7)

126
Field Description
Voltage Voltage of a PI.
PD Description Type and location description for the PD connected to the PI.
# Display power supplying information for all PIs.
<Sysname> display poe interface
Interface PoE Priority CurPower Oper IEEE Detection
(W) Class Status
GE2/1/1 Enabled Low 4.4 On 1 Delivering Power
GE2/1/2 Enabled Critical 0.0 On - Disabled
GE2/1/3 Enabled Low 0.0 On - Disabled
GE2/1/4 Enabled Critical 0.0 On - Searching
GE2/1/5 Enabled Low 4.0 On 2 Delivering Power
GE2/1/6 Enabled Low 0.0 On - Disabled
GE2/1/7 Disabled Low 0.0 Off - Fault
--- On State Ports: 2; Used: 8.4(W); Remaining: 171.6(W) ---
Table 23 Command output
Field Description
Interface Interface name of a PI.
PoE
PoE status:
Enabled.
Disabled.
Priority
Power priority of a PI:
Critical (highest).
High.
Low.
CurPower Current power of a PI.
Oper
Operating status of a PI:
Off—PoE is disabled.
On—Power is being supplied to a PI correctly.
Power-lack—Remaining guaranteed power for a critical PI is
insufficient.
Power-deny—The PSE refuses to supply power. The power required
by the PD is higher than the configured power.
Power-itself—The PD is using another power supply.
Power-limit—The PSE is supplying a limited power. The PD requires
more power than the configured power, but the PSE supplies power to
the PD based on the configured power.
IEEE Class
PD power class: 0, 1, 2, 3, or 4.
If PoE is not supported, this field displays a hyphen (-).