HP MSR2000/3000/4000 Router Series Fundamentals Command Reference
174
Use undo version check ignore to enable this function.
Syntax
version check ignore
undo version check ignore
Default
The startup software images on the standby MPU are checked for version inconsistency with the current
software images on the active MPU.
Views
System view
Predefined user roles
network-admin
Usage guidelines
The following matrix shows the command and chassis compatibility:
Command MSR2000
MSR3000
MSR4000
version check ignore No No Yes
When the standby MPU starts up, this command disables the system to examine the standby MPU's
startup software images for version inconsistency with the active MPU's current software images. The
standby MPU can start up with a different software version than the active MPU.
Even though you can use this command for upgrading software, HP recommends the ISSU method to
software upgrade. The startup software version check function might fail to work because the software
versions of the MPUs are incompatible.
To avoid anomalies, do not disable startup software version check for the standby MPU unless for
software upgrade.
To make sure the standby MPU always runs the same software images as the active MPU, configure both
the version auto-update enable command and the undo version check ignore command.
Examples
# Enable startup software version check for the standby MPU.
<Sysname> system-view
[Sysname] undo version check ignore
Related commands
version auto-update enable