HP MSR2000/3000/4000 Router Series Interface Command Reference
104
Field Descri
p
tion
Source clock
Source clock used by the interface: master for the
internal clock or slave for the line clock.
Data-coding Normal or inverted.
Idle code 0x7E or 0xFF.
Itf type Type of interframe filling tag: 0x7E or 0xFF.
Itf number Number of interframe filling tags.
Loop back
Loopback setting on the interface: local, payload,
remote, or not set.
Alarm State Alarm state.
Receiver alarm state is Loss-of-Signal Type of received alarm: none, LOS, LOF, RAI, or AIS.
Transmitter is sending remote alarm. Type of transmitted alarm: RAI, or none.
Pulse density violation detected
The detected pulse density is incompliant with the
specification.
SendLoopCode History:
Inband-llb-up: 0 times, Inband-llb-down: 0 times
Fdl-ansi-llb-up: 0 times, Fdl-ansi-llb-down: 0 times
Fdl-ansi-plb-up: 0 times, Fdl-ansi-plb-down: 0 times
Fdl-att-plb-up: 0 times, Fdl-att-plb-down: 0 times
History of loopback code sending to the peer end,
including the number of transmissions for each type of
code, and the type of the last sent code.
BERT state
BERT state: completed, stopped (not completed), or
running.
Test pattern Test pattern in use (2^20 or 2^15).
Status Whether is synchronization is being performed.
Sync Detected Number of detected synchronizations.
Time Duration of the BERT test.
Time past Time that has elapsed.
Bit Errors (since test started)
Number of bit errors received since start of the BERT
test.
Bits Received (since test started) Number of bits received since start of the BERT test.
Bit Errors (since latest sync)
Number of bit errors received since last
synchronization.
Bits Received (since latest sync) Number of bits received since last synchronization.
Historical Statistics Historical statistics.
Last clearing of counters Counter clearing records.