HP MSR2000/3000/4000 Router Series Interface Command Reference

110
For the PRI set, the system automatically creates a serial interface that is logically equivalent to an ISDN
PRI interface. The serial interface is named in the form of serial number:23, where number is the number
of the CT1/PRI interface on which the serial interface is created.
Because a channel set and a PRI set cannot coexist on a CT1/PRI interface, your PRI set creation attempt
will fail if the channel-set command is configured.
Examples
# Bundle timeslots 1, 2, and 8 through 12 into a PRI set on CT1/PRI interface T1 2/0.
<Sysname> system-view
[Sysname] controller t1 2/0
[Sysname-T1 2/0] pri-set timeslot-list 1,2,8-12
Related commands
channel-set
reset counters controller t1
Use reset counters controller t1 to clear the controller counter for a CT1/PRI interface.
Syntax
reset counters controller t1 [ interface-number ]
Views
User view
Predefined user roles
network-admin
Parameters
interface-number: Specifies a CT1/PRI interface by its number. If you do not specify this argument, the
command clears the controller counter for all CT1/PRI interfaces.
Usage guidelines
The reset counters interface command clears the counters of all interfaces. To clear the controller counter
of individual CT1/PRI interfaces, use the reset counters controller t1 command.
Examples
# Clear the controller counter for CT1/PRI interface T1 2/0.
<Sysname> reset counters controller t1 2/0
Related commands
display controller t1
sendloopcode
Use sendloopcode to send remote loopback control code.
Syntax
sendloopcode { fdl-ansi-llb-down | fdl-ansi-llb-up | fdl-ansi-plb-down | fdl-ansi-plb-up |
fdl-att-plb-down | fdl-att-plb-up | inband-llb-down | inband-llb-up }