HP MSR2000/3000/4000 Router Series Interface Command Reference
144
Examples
# Display information about interface E3 2/0.
<Sysname> display controller e3 2/0
E3 2/0
Current state: UP
Description: E3 2/0 Interface
Frame-format: G751, line code: HDB3, clock: slave
national-bit: 1, Current mode: CE3, loopback: not set, Alarm: none
ERROR: 2 BPV, 0 EXZ, 0 FrmErr, 0 FEBE
BERT state: (stopped, not completed)
Test pattern: 2^7, Status: Not Sync, Sync Detected: 0
Time: 2 minutes Time past: 2 minutes
Bit errors (since test started): 0 bits
Bits received (since test started): 0 Mbits
Bit errors (since latest sync): 0 bits
Bits received (since latest sync): 0 Mbits
E3 2/0 CE1 1: up
Frame-format: NO-CRC4, clock: slave, loopback: not set
Receiver alarm state: none
BERT state: (stopped, not completed)
E3 2/0 CE1 2: up
Frame-format: NO-CRC4, clock: slave, loopback: not set
Receiver alarm state: none
BERT state: (stopped, not completed)
E3 2/0 CE1 3: up
Frame-format: NO-CRC4, clock: slave, loopback: not set
Receiver alarm state: none
BERT state: (stopped, not completed)
E3 2/0 CE1 4: up
Frame-format: NO-CRC4, clock: slave, loopback: not set
Receiver alarm state: none
BERT state: (stopped, not completed)
E3 2/0 CE1 5: up
Frame-format: NO-CRC4, clock: slave, loopback: not set
Receiver alarm state: none
BERT state: (stopped, not completed)
E3 2/0 CE1 6: up
Frame-format: NO-CRC4, clock: slave, loopback: not set
Receiver alarm state: none
BERT state: (stopped, not completed)
E3 2/0 CE1 7: up
Frame-format: NO-CRC4, clock: slave, loopback: not set
Receiver alarm state: none
BERT state: (stopped, not completed)
E3 2/0 CE1 8: up
Frame-format: NO-CRC4, clock: slave, loopback: not set
Receiver alarm state: none
BERT state: (stopped, not completed)