HP MSR2000/3000/4000 Router Series Interface Command Reference
146
Field Descri
p
tion
Alarm Alarm state.
BERT state
BERT state: completed, stopped (not completed), or
running.
Test pattern Test pattern in use: 2^20 or 2^15.
Status Whether is being synchronized.
Sync Detected Number of detected synchronizations.
Time Duration of the BERT test.
Time past Time that has elapsed.
Bit Errors (since test started)
Number of bit errors received since start of the BERT
test.
Bits Received (since test started) Number of bits received since start of the BERT test.
Bit Errors (since latest sync)
Number of bit errors received since last
synchronization.
Bits Received (since latest sync) Number of bits received since last synchronization.
E3 2/0 CE1 1 Physical state of the E1 channel: up or down.
Frame-format
Frame format configured on the E1 channel: ESF or
SF.
clock
Source clock used by the E1 channel: master for the
internal clock or slave for the line clock.
loopback Loopback setting on the E1 channel.
Receiver alarm state
Alarm state of received by the E1 channel, LOS, LOF,
AIS, or RAI.
BERT state
BERT state: completed, stopped (not completed), or
running.
Related commands
reset counters controller e3
e1 bert
Use e1 bert to enable BERT test for an E1 channel created on a CE3 interface.
Use undo e1 bert to disable BERT test.
Syntax
e1 line-number bert pattern { 2^11 | 2^15 | 2^20 | 2^23 | qrss } time number [ unframed ]
undo e1 line-number bert
Default
No BERT test is performed.
Views
CE3 interface view