HP MSR2000/3000/4000 Router Series Interface Command Reference

59
<Sysname> system-view
[Sysname] interface async 6/4/0
[Sysname-Async6/4/0] eliminate-pulse
Related commands
physical-mode
idle-code
Use idle-code to set the line idle code of the synchronous serial interface to 0xFF.
Use undo idle-code to restore the default.
Syntax
idle-code { 7e | ff }
undo idle-code
Default
The line idle code of a synchronous serial interface is 0x7E.
Views
Synchronous serial interface view
Predefined user roles
network-admin
Parameters
7e: Specifies the 0x7E line idle code.
ff: Specifies the 0xFF line idle code.
Usage guidelines
In most cases, a synchronous serial interface uses 0x7E to identify the idle state of the line. You might
need to set the line idle code to 0xFF to interoperate with devices that use 0xFF (high level of all ones) as
line idle code.
Examples
# Set the line idle code of synchronous serial interface Serial 2/0 to 0xFF.
<Sysname> system-view
[Sysname] interface serial 2/0
[Sysname-Serial2/0] idle-code ff
interface async
Use interface async to enter asynchronous interface view.
Syntax
interface async interface-number
Views
System view