89
Description: E1 2/0 Interface
Basic Configuration:
Work mode: E1 framed, Cable type: 75 Ohm unbalanced
Frame-format: no-crc4, Line code: hdb3, Source clock: slave
Idle code: 7e, Itf type: 7e, Itf number: 4, Loop back: not set
Alarm State:
Receiver alarm state is None
Historical Statistics:
Last clearing of counters: Never
Data in current interval (150 seconds elapsed):
Loss Frame Alignment: 0 seconds, Framing Error: 0 seconds
CRC Error: 0 seconds, Alarm Indication: 0 seconds
Loss-of-signals: 0 seconds, Code Violations: 0 seconds
Slip: 0 seconds, E-Bit error: 0 seconds
Table 14 Command output
Field Description
E1 2/0
Current state
State of the interface.
Description Description of the interface.
Work mode Work mode of the interface: E1 or CE1.
Cable type Cable type of the interface.
Frame-format Frame format of the interface: crc4 or no crc4.
Source Clock Work mode of the source clock of the interface: master or slave.
Line Code Line code: AMI or HDB3.
Idle Code Idle code; 7E or FF.
Itf type Interframe filling tag: 7E or FF.
Itf number Number of interframe filling tags between two successive frames.
Loopback Loopback state.
Alarm State Alarm state.
Historical Statistics Statistics on the interface.
Last clearing of counters The last time when statistics on the interface were cleared.
Data in current interval (150 seconds
elapsed):
Loss Frame Alignment: 0 seconds,
Framing Error: 0 seconds
CRC Error: 0 seconds, Alarm
Indication: 0 seconds
Loss-of-signals: 0 seconds, Code
Violations: 0 seconds
Slip: 0 seconds, E-Bit error: 0 seconds
Error statistics in the current interval.