HP MSR2000/3000/4000 Router Series Interface Module Guide
147
Figure 137 Connect an E1 75-ohm cable
• If you want to extend the cable, connect each BNC connector of the E1 75-ohm cable to one end
of a coaxial connector, and connect the remote device to the other end of the coaxial connector
through an E1 75-ohm trunk cable.
Figure 138 Connect an E1 75-ohm cable
• If the impedance of the E1 interface on the remote device is 120 ohms, you must use an impedance
converter to adapt the impedance.
Figure 139 Connect an impedance converter
Connecting a 4-port E1 75-ohm cable (D25 <----> D15)
1. Connect the D25 connector of the 4-port E1 75-ohm cable to the D25 interface of the interface
module and fasten the bolts to fix the cable.
……
Coaxial connector
1/2/4/8-port E1 75-ohm cable
E1 / E1-F
(75ohm)
TX
RX
Device
(75ohm E1 Port)
TX
RX
75-ohm adapter cable
……