HP MSR2000/3000/4000 Router Series Layer 2 - WAN Command Reference

149
[Sysname-Serial2/0] dialer timer compete 10
dialer timer enable
Use dialer timer enable to set the link holddown timer.
Use undo dialer timer enable to restore the default.
Syntax
dialer timer enable seconds
undo dialer timer enable
Default
The link holddown timer is 5 seconds.
Views
Dialup interface (physical or dialer interface) view
Predefined user roles
network-admin
Parameters
seconds: Holddown timer value, setting the interval for originating a call to bring up a link after it is
disconnected. The value range for this argument is 5 to 65535 seconds.
Usage guidelines
A holddown timer starts upon disconnection of a link. The call attempt to bring up this link can be made
only after the timer expires. This is to prevent a remote PBX from being overloaded.
To make sure the server has enough time to place a return call, the link holddown timer of the client
should be 10 seconds longer than that of the server. HP recommends that you set the link holddown timer
to 5 seconds (the default) on the server, and 15 seconds on the client.
Examples
# Set the interval for DDR to make the next call attempt to 15 seconds.
<Sysname> system-view
[Sysname] interface serial 2/0
[Sysname-Serial2/0] dialer timer enable 15
dialer timer idle
Use dialer timer idle to set the link idle-timeout timer.
Use undo dialer timer idle to restore the default.
Syntax
dialer timer idle seconds [ in | in-out ]
undo dialer timer idle
Default
The link idle-timeout timer is 120 seconds, and only outgoing interesting packets reset this timer.