HP MSR2000/3000/4000 Router Series Layer 2 - WAN Configuration Guide
30
Ste
p
Command
Remarks
6. Associate the interface with
the dial access control rule by
associating the interface with
the corresponding dialer
access group.
dialer-group group-number
By default, a dialer interface is
not assigned to any dialer
group.
7. Configure the link-idle
timeout timer.
dialer timer idle seconds [ in | in-out ]
The default setting is 120
seconds.
When this timer is set to 0
seconds, the PPPoE session
operates in permanent mode.
Otherwise, the PPPoE session
operates in on-demand mode.
8. Configure the DDR
application to operate in
diagnostic mode.
dialer diagnose [ interval seconds ]
By default, the DDR application
operates in non-diagnostic
mode.
When DDR operates in
diagnostic mode, the link-idle
timeout timer is ignored.
9. Set the auto-dial interval.
dialer timer autodial seconds
The default setting is 300
seconds.
In permanent or diagnostic
mode, DDR starts the auto-dial
timer after the link is
disconnected and originates a
new call when the auto-dial
timer expires.
HP recommends that you set a
shorter auto-dial interval for
DDR to soon originate a new
call.
Configuring a PPPoE session
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A
2. Enter Layer 3 Ethernet
interface/subinterface, Layer 3
virtual Ethernet
interface/subinterface, VLAN
interface, or WLAN Ethernet
interface view.
interface interface-type
interface-number
N/A
3. Create a PPPoE session and specify a
dialer bundle for the session.
pppoe-client dial-bundle-number
number [ no-hostuniq ]
By default, no PPPoE
sessions are created.
The number argument in this
command must take the
same value as the
configured dialer interface
number.