HP MSR2000/3000/4000 Router Series Network Management and Monitoring Command Reference
169
Parameters
interface-type interface-number: Specifies an interface by its type and number. If no interface is specified,
the command displays history samples for all interfaces that have an RMON history control entry.
Usage guidelines
RMON uses the etherHistoryTable object to store the history samples of Ethernet statistics for Ethernet
interfaces.
To collect history samples for an Ethernet interface, you must first create a history control entry on the
interface.
To configure the number of history samples that can be displayed and the history sampling interval, use
the rmon history command.
Examples
# Display the RMON history control entry and history samples for Ethernet 1/1.
<Sysname> display rmon history ethernet 1/1
HistoryControlEntry 6 owned by user1 is VALID.
Sampled interface : Ethernet 1/1 <ifIndex.117>
Sampling interval : 8(sec) with 3 buckets max
Sampling record 1 :
dropevents : 0 , octets : 5869
packets : 54 , broadcast packets : 9
multicast packets : 23 , CRC alignment errors : 0
undersize packets : 0 , oversize packets : 0
fragments : 0 , jabbers : 0
collisions : 0 , utilization : 0
Sampling record 2 :
dropevents : 0 , octets : 5367
packets : 55 , broadcast packets : 1
multicast packets : 7 , CRC alignment errors : 0
undersize packets : 0 , oversize packets : 0
fragments : 0 , jabbers : 0
collisions : 0 , utilization : 0
Sampling record 3 :
dropevents : 0 , octets : 936
packets : 10 , broadcast packets : 0
multicast packets : 6 , CRC alignment errors : 0
undersize packets : 0 , oversize packets : 0
fragments : 0 , jabbers : 0
collisions : 0 , utilization : 0
HistoryControlEntry 7 owned by user1 is VALID.
Sampled interface : Ethernet 1/1 <ifIndex.117>
Sampling interval : 9(sec) with 1 buckets max
Sampling record 1 :
dropevents : 0 , octets : 1150
packets : 12 , broadcast packets : 0
multicast packets : 8 , CRC alignment errors : 0
undersize packets : 0 , oversize packets : 0
fragments : 0 , jabbers : 0