HP MSR2000/3000/4000 Router Series Network Management and Monitoring Command Reference

173
Field Descri
p
tion
Alarm sent upon entry startup
Alarm that can be generated when the entry becomes valid (MIB object
hh3cRmonExtAlarmStartupAlarm):
risingAlarm—Generates a rising alarm if the first sample after the entry
becomes valid is greater than or equal to the rising threshold.
fallingAlarm—Generates a falling alarm if the first sample after the
entry becomes valid is less than or equal to the rising threshold.
risingOrFallingAlarm—Generates a rising alarm or falling alarm if the
first sample after the entry becomes valid crosses the rising threshold or
falling threshold.
The default is risingOrFallingAlarm.
Entry lifetime
Lifetime of the entry.
If the lifetime is set to forever (MIB object is hh3cRmonExtAlarmStatType),
the entry never expires.
If the lifetime is set to an amount of time (MIB object
hh3cRmonExtAlarmStatType), the entry is removed when the timer expires.
Latest value Most recent sampled value (MIB object hh3cRmonExtAlarmValue).
Related commands
rmon prialarm
display rmon statistics
Use display rmon statistics to display RMON statistics.
Syntax
display rmon statistics [ interface-type interface-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
interface-type interface-number: Specifies an interface by its type and number. If no interface is specified,
the command displays RMON statistics for all interfaces.
Usage guidelines
This command displays the cumulative interface statistics for the period from the time the statistics entry
was created to the time the command was executed. The statistics are cleared when the device reboots.
Examples
# Display RMON statistics for Ethernet 1/1.
<Sysname> display rmon statistics ethernet 1/1
EtherStatsEntry 1 owned by user1 is VALID.
Interface : Ethernet1/1<ifIndex.3>
etherStatsOctets : 43393306 , etherStatsPkts : 619825