HP MSR2000/3000/4000 Router Series Network Management and Monitoring Command Reference
315
# Enable core file generation for process routed and set the maximum number of core files to 5.
<Sysname> process core maxcore 5 name routed
Related commands
• display context
• exception filepath
exception filepath
Use exception filepath to specify the directory to save core files.
Use undo exception filepath to remove the specified directory.
Syntax
exception filepath directory
undo exception filepath directory
Default
The core files are stored in the root directory of Flash or a CF card.
Views
User view
Predefined user roles
network-admin
Parameters
directory: Specifies the directory to save core files, which can only be the root directory of Flash or a CF
card.
Usage guidelines
Each MPU has a default directory to store core files. You can use this command to change the directory
on the active MPU and the standby MPU.
If no directory is specified or the specified directory is not accessible, the system cannot store core files
or record context information for process exceptions.
Examples
# Specify the directory to save core files as cfa0:/.
<Sysname> exception filepath cfa0:/
Related commands
• display exception filepath
• process core
display exception filepath
Use display exception filepath to display the core file directory.