HP MSR2000/3000/4000 Router Series Network Management and Monitoring Command Reference
88
Clock source: 192.168.1.40
Session ID: 35888
Clock stratum: 2
Clock status: configured, master, sane, valid
Reference clock ID: 127.127.1.0
VPN instance: Not specified
Local mode: client, local poll interval: 6
Peer mode: server, peer poll interval: 6
Offset: 0.2862ms, roundtrip delay: 3.2653ms, dispersion: 4.5166ms
Root roundtrip delay: 0.0000ms, root dispersion: 10.910ms
Reachabilities:31, sync distance: 0.0194
Precision: 2^18, version: 3, source interface: Not specified
Reftime: d17cbba5.1473de1e Tue, May 17 2011 9:17:25.079
Orgtime: 00000000.00000000 Thu, Feb 7 2036 6:28:16.000
Rcvtime: d17cbbc0.b1959a30 Tue, May 17 2011 9:17:52.693
Xmttime: d17cbbc0.b1959a30 Tue, May 17 2011 9:17:52.693
Roundtrip delay samples: 0.007 0.010 0.006 0.011 0.010 0.005 0.007 0.003
Offset samples: 5629.55 3913.76 5247.27 6526.92 31.99 148.72 38.27 0.29
Filter order: 7 5 2 6 0 4 1 3
Total sessions: 1
Table 16 Command output
Field Descri
p
tion
Clock source IP address of the NTP server.
Clock stratum
Stratum level of the NTP server, which determines the clock
accuracy. The value is in the range of 1 to 16. A lower stratum level
represents greater clock accuracy. A stratum 16 clock is not
synchronized and cannot be used as a reference clock.
Clock status
Status of the clock source corresponding to this association:
• configured—The association was created by a configuration
command.
• dynamic—The association is established dynamically.
• master—The clock source is the primary reference source of the
current system.
• selected—The clock source has survived the clock selection
algorithm.
• candidate—The clock source is the candidate reference source.
• sane—The clock source has passed the sane authentication.
• insane—The clock source has failed the sane authentication.
• valid—The clock source is valid, which means the clock source
meets the following requirements: it has passed authentication
and is being synchronized. Its stratum level is valid, and its root
delay and root dispersion values are within their ranges.
• invalid—The clock source is invalid.
• unsynced—The clock source has not been synchronized or the
value of the stratum level is invalid.