HP MSR2000/3000/4000 Router Series Voice Command Reference

33
Usage guidelines
This command takes effect only after the echo-canceler enable command is configured.
Examples
# Disable the EC nonlinear processing function on voice interface 1/0.
<Sysname> system-view
[Sysname] subscriber-line 1/0
[Sysname-subscriber-line 1/0] undo nlp-on
Related commands
echo-canceler enable
open-trunk
Use open-trunk to enable E&M non-signaling mode.
Use undo open-trunk to disable E&M non-signaling mode.
Syntax
open-trunk { caller [ monitor interval ] | called }
undo open-trunk
Default
The E&M non-signaling mode is disabled.
Views
E&M interface view
Predefined user roles
network-admin
Parameters
caller: Enables E&M non-signaling mode on the originating device.
monitor interval: Sets the monitoring time in the range 60 to 600 seconds. If the terminating side does
not go off-hook within the specified time, the originating side re-initiates a call to the terminating side.
The monitoring timer starts immediately after this option is configured.
called: Enables E&M non-signaling mode on the terminating device.
Usage guidelines
You must configure the signal immediate command on the originating and terminating devices before
configuring this command.
Configure the open-trunk caller [ monitor interval ] command on the originating device, and configure
the open-trunk called command on the terminating device.
For the E&M non-signaling mode to work with the PLAR function, you need to configure the private-line
command on the originating device. For more information about the PLAR function, see "Configuring dial
programs."
Examples
# Enable the E&M non-signaling mode on the originating device, and specify the monitoring time as 120
seconds.