HP MSR2000/3000/4000 Router Series Voice Command Reference

39
[Sysname] subscriber-line 1/0
[Sysname-subscriber-line1/0] shutdown
signal
Use signal to configure a start mode for an E&M interface.
Use undo signal to restore the default.
Syntax
signal { delay | immediate | wink }
undo signal
Default
An E&M interface uses the immediate start mode.
Views
E&M interface view
Predefined user roles
network-admin
Parameters
delay: Specifies delay start mode.
immediate: Specifies immediate start mode.
wink: Specifies wink start mode.
Usage guidelines
You must configure the same start mode on the originating and terminating devices.
Examples
# Configure the delay mode for E&M interface 1/0.
<Sysname> system-view
[Sysname] subscriber-line 1/0
[Sysname-subscriber-line1/0] signal delay
silence-detect threshold
Use silence-detect threshold to configure silence detection-based automatic on-hook.
Use undo silence-detect to restore the default.
Syntax
silence-detect threshold threshold time time-length
undo silence-detect
Default
The silence threshold is 20, and the silence duration for automatic on-hook is 7200 seconds (2 hours).
Views
FXO interface view