HP MSR2000/3000/4000 Router Series Voice Command Reference
72
timer register-pulse
Use timer register-pulse to configure the duration of register pulse signals.
Use undo timer register-pulse to restore the default.
Syntax
timer register-pulse time
undo timer register-pulse
Default
The duration is 150 milliseconds.
Views
R2 CAS view
Predefined user roles
network-admin
Parameters
time: Specifies the duration of register pulse signals, in the range of 50 to 3000 milliseconds.
Examples
# Configure the duration of register pulse signals as 300 milliseconds.
<Sysname> system-view
[Sysname] controller e1 1/0
[Sysname-E1 1/0] timeslot-set 0 timeslot-list 1-31 signal r2
[Sysname-E1 1/0] cas 0
[Sysname-cas 1/0:0] timer register-pulse 300
timeslot-set
Use timeslot-set to create a timeslot set.
Use undo timeslot-set to delete a timeslot set.
Syntax
timeslot-set ts-set-number timeslot-list timeslots-list signal r2
undo timeslot-set ts-set-number
Default
No timeslot set is created.
Views
E1 interface view, T1 interface view
Predefined user roles
network-admin
Parameters
ts-set-number: Specifies the number of a timeslot set, in the range of 0 to 30.