HP MSR2000/3000/4000 Router Series Voice Command Reference

2
Parameters
index: Assigns a number to a busy tone type, in the range of 0 to 3. The device can record four types of
busy tones at most.
line-number: Specifies an FXO interface.
Usage guidelines
The busytone-detect auto command takes effect on only FXO interfaces.
After detecting a busy tone type by using the busytone-detect auto command, the device automatically
calculates the busy tone parameters, executes the busytone-detect custom command to record the busy
tone parameters, and executes the area custom command to validate these busy tone parameters.
Examples
# Enable automatic busy tone detection on FXO interface 2/0, and assign number 0 to the detected busy
tone parameters.
<Sysname> system-view
[Sysname] voice-setup
[Sysname-voice] busytone-detect auto 0 2/0
Related commands
area custom
busytone-detect custom
busytone-detect custom
Use busytone-detect custom to configure busy tone parameters.
Use undo busytone-detect custom to delete busy tone parameters.
Syntax
busytone-detect custom area-number index argu f1 f2 p1 p2 p3 p4 p5 p6 p7
undo busytone-detect custom index
Default
Busy tone parameters depend on the area command.
Views
Voice view
Predefined user roles
network-admin
Parameters
area-number: Specifies an area number. This argument is reserved for future use and has a fixed value
of 2.
index: Assigns a number to a busy tone type, in the range of 0 to 3. The device can record four types of
busy tones at most.
argu: This argument is reserved for future use and has a value range of 0 to 32767.
f1: Frequency 1 in Hz, in the range of 50 to 3600.
f2: Frequency 2 in Hz, in the range of 50 to 3600.