HP MSR3012/3024 Routers FIPS Enclosure Installation Guide

Phillips screwdriver
(User-supplied)
Needle-nose pliers
(User-supplied)
ESD-preventive wrist strap
(User-supplied)
Installation kit
Installing a FIPS enclosure on a router with front mounting brackets
HP MSR3012/3024 routers meet the requirement of FIPS security level 2.
Tool list
M4 countersunk-head screw
(Supplied with the router)
Mounting brackets
(Supplied with the router)
Opacity shield
M3 countersunk-
head screw
Hex bolt
Only use the screws and hex bolts that are supplied in the opacity shield kit to secure
the opacity shield.
Installation preparation
Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good
skin contact and is well grounded.
The installation procedures must be performed by qualified personnel.
Before installation, read the Compliance and Safety Manual for the compatible switch
of the opacity shield kit.
1
Face the front panel, install the front mounting brackets on both sides of the router and
secure them with M
4 countersunk-head screws, mount the router on a rack shelf (skip this
step if the router is not to be mounted on a rack), and attach the opacity shield.
Install hex bolts on the chassis as shown in the figures. (Remove the fastening screws, if any,
from where hex bolts are to be installed.)
Align the holes on the opacity shields with the hex bolts.
Press the opacity shields against the side panels, and use M3 countersunk-head screws to
secure the opacity shields.
Apply tamper-evidence labels to opacity shields, screws that secure the opacity shields,
field replaceable units (FRUs), USB ports, and air vents on interface cards and filler panels.
2