R0106-HP MSR Router Series Fundamentals Command Reference(V7)

232
RX loss of signal
RX power low
Table 40 Command output
Field Descri
p
tion
transceiver current alarm information Alarms present on the transceiver module.
RX loss of signal Received signals are lost.
RX power low Received power is low.
display transceiver diagnosis
Use display transceiver diagnosis to display the current values of the digital diagnosis parameters on
transceiver modules.
Syntax
display transceiver diagnosis interface [ interface-type interface-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
interface [ interface-type interface-number ]: Specifies an interface by its type and number. If no interface
is specified, this command displays the current values of the digital diagnosis parameters on every
transceiver module.
Usage guidelines
This command cannot display information about some transceiver modules.
Examples
# Display the current values of the digital diagnosis parameters on the transceiver module in interface
GigabitEthernet 2/1/1.
<Sysname> display transceiver diagnosis interface gigabitethernet 2/1/1
GigabitEthernet2/1/1 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
36 3.31 6.13 -35.64 -5.19
Alarm thresholds:
Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
High 50 3.55 1.44 -10.00 5.00
Low 30 3.01 1.01 -30.00 0.00
Table 41 Command output
Field Descri
p
tion
transceiver diagnostic information Digital diagnosis information of the transceiver module in the interface.