R0106-HP MSR Router Series Fundamentals Command Reference(V7)

244
Default
Power supply management is disabled.
Views
System view
Predefined user roles
network-admin
Examples
# Enable power supply management.
<Sysname> system-view
[Sysname] power-supply policy enable
power-supply policy redundant
Use power-supply policy redundant to specify the number of redundant power supplies.
Use undo power-supply policy redundant to restore the default.
Syntax
power-supply policy redundant module-count
undo power-supply policy redundant
The following matrix shows the support of MSR routers for the command:
Hardware Command
com
p
atibilit
y
MSR2000 No
MSR3000 No
MSR4000 Yes
Default
The number of redundant power supplies is 0.
Views
System view
Predefined user roles
network-admin
Parameters
module-count: Specifies the number of redundant power supplies. To view the value range, use the online
help for this command at the CLI. The upper limit of the value range is the maximum number of redundant
power supplies supported by the system. Depending on the number of the inserted interface cards and
power consumption, the actual number of redundant power supplies that you can configure is smaller
than or equal to the maximum number of redundant power supplies supported by the system.
Usage guidelines
The configuration of this command takes effect only when power supply management is enabled.