152
Notification Triggering condition Remarks
Critical alarm-removed
notification
The amount of free memory space
increases to or above the severe
alarm threshold.
N/A
Severe alarm-removed
notification
The amount of free memory space
increases to or above the minor
alarm threshold.
N/A
Minor alarm-removed
notification
The amount of free memory space
increases to or above the normal
state threshold.
N/A
Figure 57 Memory alarm notification and alarm-removed notification
To set memory usage thresholds:
Step Command Remarks
1. Enter system view.
system-view N/A
2. Set memory usage
thresholds.
MSR2000/MSR3000:
memory-threshold minor minor-value
severe severe-value critical
critical-value normal normal-value
MSR4000:
memory-threshold [ slot slot-number
[ cpu cpu-number ] ] minor
minor-value severe severe-value
critical critical-value normal
normal-value
The defaults are as follows:
Minor alarm threshold—96 MB.
Severe alarm threshold—64 MB.
Critical alarm threshold—48 MB.
Normal state threshold—128
MB.