R0106-HP MSR Router Series Interface Command Reference(V7)
104
Parameters
interface-number: Specifies a CT1/PRI interface by its number. If you do not specify this argument, the
command displays information about all CT1/PRI interfaces.
Examples
# Display information about T1 2/4/0.
<Sysname> display controller t1 2/4/0
T1 2/4/0
Current state: DOWN
Description: T1 2/4/0 Interface
Basic Configuration:
Work mode: T1 framed, Cable type: 100 Ohm balanced
Frame-format: esf, fdl: none, Line code: b8zs
Source clock: slave, Data-coding: normal
Idle code: ff, Itf type: ff, Itf number: 2
Loop back: not set
Alarm State:
Receiver alarm state is Loss-of-Signal
Transmitter is sending remote alarm
Pulse density violation detected
SendLoopCode History:
Inband-llb-up: 0 times, Inband-llb-down: 0 times
Fdl-ansi-llb-up: 0 times, Fdl-ansi-llb-down: 0 times
Fdl-ansi-plb-up: 0 times, Fdl-ansi-plb-down: 0 times
Fdl-att-plb-up: 0 times, Fdl-att-plb-down: 0 times
BERT state:(stopped, not completed)
Test pattern: 2^15, Status: Not Sync, Sync Detected: 0
Time: 0 minutes, Time past: 0 minutes
Bit Errors (since test started): 0 bits
Bits Received (since test started): 0 Kbits
Bit Errors (since latest sync): 0 bits
Bits Received (since latest sync): 0 Kbits
Historical Statistics:
Last clearing of counters: Never
Data in current interval (285 seconds elapsed):
Line Code Violations: 0, Path Code Violations: 0
Ais Alarm: 0 seconds, Los Alarm: 286 seconds
Slip: 7 seconds, Fr Loss: 286 seconds
Line Err: 0 seconds, Degraded: 0 minutes
Errored: 0 seconds, Bursty Err: 0 seconds
Severely Err: 0 seconds, Unavail: 286 seconds
Data in Interval 1:
Line Code Violations: 0, Path Code Violations: 0
Ais Alarm: 0 seconds, Los Alarm Secs: 901 seconds
Slip: 22 seconds, Fr Loss: 901 seconds
Line Err: 0 seconds, Degraded: 0 minutes
Errored: 0 seconds, Bursty Err: 0 seconds
Severely Err: 0 seconds, Unavail: 901 seconds