sdvalue: Specifies an SD alarm threshold value in the format of 10e-sdvalue. The value range for this
argument is 3 to 9. The greater the value, the smaller the SD alarm threshold.
sf: Sets the SF alarm threshold. The SF alarm threshold must be higher than the SD alarm threshold.
sfvalue: Specifies an SF alarm threshold value in the format of 10e-sfvalue. The value range for this
argument is 3 to 9. The greater the value, the smaller the SF alarm threshold.
Usage guidelines
SD and SF alarms indicate current line performance. The device generates SD or SF alarms when it
detects a certain amount of B2 errors. SF alarms are more severe than SD alarms.
When the number of B2 errors reaches the SD alarm threshold, the device generates an SD alarm.
When the number of B2 errors increases to the SF alarm threshold, the device generates an SF
alarm.
Examples
# Set the SD threshold to 10e-4 on CPOS 2/4/0.
<Sysname> system-view
[Sysname] interface cpos 2/4/0
[Sysname-Cpos2/4/0] threshold sd 4