R0106-HP MSR Router Series Interface Command Reference(V7)

17
Loopback is not set
Media type is twisted pair,Port hardware type is 1000_BASE_T_AN_SFP
Unknown-speed mode, unknown-duplex mode
Link speed type is autonegotiation, link duplex type is autonegotiation
Flow-control is not enabled
The Maximum Frame Length is 9216
Allow jumbo frame to pass
Broadcast MAX-ratio: 100%
Multicast MAX-ratio: 100%
Unicast MAX-ratio: 100%
PVID: 1
Mdi type: automdix
Port link-type: access
Tagged Vlan: none
UnTagged Vlan: 1
Port priority: 2
Last clearing of counters: 14:34:09 Tue 11/01/2011
Peak value of input: 0 bytes/sec, at 2013-07-17 22:06:19
Peak value of output: 0 bytes/sec, at 2013-07-17 22:06:19
Last 300 seconds input: 0 packets/sec 0 bytes/sec -%
Last 300 seconds output: 0 packets/sec 0 bytes/sec -%
Input (total): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Input (normal): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Input: 0 input errors, 0 runts, 0 giants, 0 throttles
0 CRC, 0 frame, 0 overruns, 0 aborts
0 ignored, 0 parity errors
Output (total): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Output (normal): 0 packets, 0 bytes
0 unicasts, 0 broadcasts, 0 multicasts, 0 pauses
Output: 0 output errors, 0 underruns, 0 buffer failures
0 aborts, 0 deferred, 0 collisions, 0 late collisions
0 lost carrier, 0 no carrier
Table 4 Command output
Field Description
Current state
State of the Ethernet interface:
Administratively DOWN—The Ethernet interface was shut down
with the shutdown command. The interface is administratively
down.
DOWN—The Ethernet interface is administratively up but
physically down (possibly because no physical link is present or
the link has failed).
UP—The Ethernet interface is both administratively and
physically up.