baudrate: Specifies a baud rate (in bps) for a serial interface.
Usage guidelines
The baud rate range that is available with synchronous serial interfaces depends on the applied physical
electric specifications.
For V.24 DTE/DCE, available baud rates (in bps) are:
Baud rates
1200 9600 56000
2400 19200 57600
4800 38400 64000
For V.35 DCE/DCE, X.21 DTE/DCE, EIA/TIA-449 DTE/DCE, and EIA-530 DTE/DCE, available
baud rates (in bps) are:
Baud rates
1200 57600 384000
2400 64000 512000
4800 72000 1024000
9600 115200 2048000
19200 128000 4096000
38400 192000
56000 256000
Take the physical electric specifications of the cable into consideration when you set the baud rate for a
serial interface.
The baud rate adopted by a DCE-DTE pair is determined by the DCE.
Examples
# Set the baud rate of Serial 2/1/0 at the DCE side to 115200 bps.
<Sysname> system-view
[Sysname] interface serial 2/1/0
[Sysname-Serial2/1/0] baudrate 115200
Related commands
virtualbaudrate
clock
Use clock to set the clock selection mode for a synchronous serial interface.
Use undo clock to restore the default.
Syntax
clock { dteclk1 | dteclk2 | dteclk3 | dteclk4 | dteclk5 | dteclkauto }