R0106-HP MSR Router Series Interface Command Reference(V7)

69
If you specify an asynchronous interface, this command clears statistics for the specified interface.
Examples
# Clear statistics for Async 2/4/0.
<Sysname> reset counters interface async 2/4/0
Related commands
display interface async
reverse-rts
Use reverse-rts to reverse RTS signal.
Use undo reverse-rts to restore the default.
Syntax
reverse-rts
undo reverse-rts
Default
RTS signal reverse is disabled.
Views
Synchronous serial interface view
Predefined user roles
network-admin
Usage guidelines
When this command is configured, the remote end is not allowed to send data while the local end is
sending data.
Use this command only for debugging purposes.
Examples
# Reverse the RTS signal.
<Sysname> system-view
[Sysname] interface serial 2/1/0
[Sysname-Serial2/1/0] reverse-rts
virtualbaudrate
Use virtualbaudrate to set a virtual baud rate for a DTE-side interface.
Use undo virtualbaudrate to remove the virtual baud rate.
Syntax
virtualbaudrate virtualbaudrate
undo virtualbaudrate
Default
The virtual baud rate for a synchronous serial interface is 64000 bps.
Views
Synchronous serial interface view