R0106-HP MSR Router Series MPLS Command Reference(V7)
104
Views
MPLS TE view
Predefined user roles
network-admin
Parameters
interval: Specifies the interval at which IGP floods TE information, in the range of 0 to 3600 seconds.
Usage guidelines
When the reservable bandwidth of a link changes, IGP floods the link TE information to notify network
devices of the change. You can use the mpls te bandwidth change thresholds command to configure IGP
to flood only significant bandwidth changes of a link to prevent excessive IGP flooding. The bandwidth
changes that cannot trigger immediate flooding are flooded at the interval configured by the
link-management periodic-flooding timer command.
If you set the interval to 0, the periodical flooding function is disabled. If you set the interval to a value
less than 30 seconds (1 to 29 seconds), the device automatically sets the interval to 30 seconds.
After you execute this command, the configured interval takes effect immediately.
Examples
# Configure IGP to flood TE information every 100 seconds.
<Sysname> system-view
[Sysname] mpls te
[Sysname-te] link-management periodic-flooding timer 100
Related commands
mpls te bandwidth change thresholds
member interface
Use member interface to specify a member interface for a tunnel bundle interface.
Use undo member interface to delete a member interface from a tunnel bundle interface.
Syntax
member interface tunnel tunnel-number [ load-share value ]
undo member interface tunnel tunnel-number
Default
No member interface is specified for a tunnel bundle interface.
Views
Tunnel bundle interface view
Predefined user roles
network-admin
Parameters
tunnel tunnel-number: Specifies a member interface by its interface number.
load-share value: Configures a weight for a member interface, in the range of 1 to 65535. The default