R0106-HP MSR Router Series Network Management and Monitoring Command Reference(V7)

125
Electric Current : 244 mA
Voltage : 51.7 V
PD Description : IP Phone For Room 101
Table 22 Command output
Field Description
PoE status
PoE status:
Enabled.
Disabled.
Power Priority
Power supply priority of the PI:
Critical (highest).
High.
Low.
Oper
Operating status of a PI:
Off—PoE is disabled.
On—Power is being supplied to a PI correctly.
Power-lack—Remaining guaranteed power for a critical PI is
insufficient.
Power-deny—The PSE refuses to supply power. The power required
by the PD is higher than the configured power.
Power-itself—The PD is using another power supply.
Power-limit—The PSE is supplying a limited power. The PD requires
more power than the configured power, but the PSE supplies power to
the PD based on the configured power.
IEEE Class
PD power class: 0, 1, 2, 3, or 4.
If PoE is not supported, this field displays a hyphen (-).
Detection Status
Power detection status of a PI:
Disabled—The PoE function is disabled.
Searching—The PI is searching for the PD.
Delivering power—The PI is supplying power to the PD.
Fault—A fault has occurred during the test.
Test—The PI is undergoing a test.
Other fault—A fault has caused the PSE to enter the idle status.
PD disconnected—The PD is disconnected.
Power Mode
Power mode of a PI:
Signal—Power is being supplied over signal cables.
Spare—Power is being supplied over spare cables.
Current Power
Current power of a PI, including PD consumption power and transmission
loss.
Transmission loss usually does not exceed 1 watt.
Average Power Average power of a PI.
Peak Power Peak power of a PI.
Max Power Maximum power of a PI.
Electric Current Current of a PI.