R0106-HP MSR Router Series Network Management and Monitoring Command Reference(V7)
127
Field Description
Detection Status
Power detection status of a PI:
• Disabled—PoE function is disabled.
• Searching—The PI is searching for the PD.
• Delivering Power—The PI is supplying power for the PD.
• Fault—A fault has occurred during the test.
• Test—The PI is undergoing a test.
• Other fault—A fault has caused the PSE to enter the idle status.
• PD disconnected—The PD is disconnected.
On State Ports Number of PIs that are supplying power.
Used Power consumed by the current PI.
Remaining Total remaining power of the system.
display poe interface power
Use display poe interface power to display power information for PIs.
Syntax
display poe interface power [ interface-type interface-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
interface-type interface-number: Specifies an interface by its type and number.
Usage guidelines
If you do not specify any interface, this command displays power information for all PIs.
Examples
# Display power information for GigabitEthernet 2/1/1.
<Sysname> display poe interface power gigabitethernet 2/1/1
Interface Current Peak Max PD Description
(W) (W) (W)
GE2/1/1 15.0 15.3 15.4 Access Point on Room 509 for Peter
# Display power information for all PIs.
<Sysname> display poe interface power
Interface Current Peak Max PD Description
(W) (W) (W)
GE2/1/25 4.4 4.5 4.6 IP Phone in Room 309 for Peter Smith
GE2/1/26 4.4 4.5 15.4 IP Phone in Room 409 for Peter Pan
GE2/1/27 15.0 15.3 15.4 Access Point in Room 509 for Peter
GE2/1/28 0.0 0.0 0.0 IP Phone in Room 609 for Peter John