Default
No alarm entries have been created.
Views
System view
Predefined user roles
network-admin
Parameters
entry-number: Specifies an alarm entry index in the range of 1 to 65535.
alarm-variable: Specifies an alarm variable, a string of 1 to 255 characters. You can only specify
variables that can be parsed as an ASN.1 INTEGER value (INTEGER, INTEGER32, Unsigned32,
Counter32, Counter64, Gauge, or TimeTicks) for the alarm-variable argument. The alarm variables must
use one of the following formats:
Format Exam
p
les
Dotted OID format:
entry.integer.instance
1.3.6.1.2.1.2.1.10.1
Object name.instance
etherStatsOctets.1
etherStatsPkts.1
etherStatsBroadcastPkts.1
ifInOctets.1
ifInUcastPkts.1
ifInNUcastPkts.1
sampling-interval: Sets the sampling interval in the range of 5 to 65535 seconds.
absolute: Specifies absolute sampling. RMON compares the value of the variable with the rising and
falling thresholds at the end of the sampling interval.
delta: Specifies delta sampling. RMON subtracts the value of the variable at the previous sample from
the current value, and then compares the difference with the rising and falling thresholds.
startup-alarm: Specifies alarms that can be generated for the first sample that is collected after the alarm
entry becomes valid. If no alarm is specified, RMON can generate a rising alarm or a falling alarm
depending on the first sample.
rising: Generates a rising alarm if the first sample is greater than or equal to the rising threshold.
falling: Generates a falling alarm if the first sample is less than or equal to the rising threshold.
rising-falling: Generates a rising alarm if the first sample crosses the rising threshold, or generates a
falling alarm if the first sample crosses the falling threshold.
rising-threshold threshold-value1 event-entry1: Sets the rising threshold. The threshold-value1 argument
represents the rising threshold in the range of –2147483648 to +2147483647. The event-entry1 argument
represents the index of the event that is triggered when the rising threshold is crossed. The value range
for the event-entry1 argument is 0 to 65535. If 0 is specified, the alarm does not trigger any event.
falling-threshold threshold-value2 event-entry2: Sets the falling threshold. The threshold-value2 argument
represents the falling threshold in the range of –2147483648 to +2147483647. The event-entry2