R0106-HP MSR Router Series Network Management and Monitoring Command Reference(V7)

323
The version 9 template is not updated on a NetStream server.
To avoid this situation, configure the refresh frequency for version 9 templates so that NetStream servers
can refresh them.
The refresh frequency and the refresh interval can both be configured, and the template is resent when
either of the conditions is reached.
Examples
# Configure the device to wait until 100 packets are sent before resending a NetStream version 9
template to NetStream servers.
<Sysname> system-view
[Sysname] ip netstream export v9-template refresh-rate packet 100
Related commands
ip netstream export v9-template refresh-rate time
ip netstream export v9-template refresh-rate time
Use ip netstream export v9-template refresh-rate time to configure the refresh interval for NetStream
version 9 templates. Then, the templates are sent after the specified time period.
Use undo ip netstream export version to restore the default.
Syntax
ip netstream export v9-template refresh-rate time minutes
undo ip netstream export v9-template refresh-rate time
Default
Version 9 templates are resent every 30 minutes.
Views
System view
Predefined user roles
network-admin
Parameters
minutes: Specifies the refresh interval that the device waits before NetStream version 9 templates are sent
to NetStream servers. The value range is 1 to 3600 minutes.
Usage guidelines
Version 9 is template-based and supports user-defined formats. A NetStream-enabled device must
periodically resend the updated template to NetStream servers, because the servers do not permanently
save the template. The server cannot associate the statistics with their proper fields when the following
conditions exist:
The version 9 template is changed on the NetStream-enabled device.
The version 9 template is not updated on a NetStream server.
To avoid this situation, configure the refresh interval for version 9 templates so that NetStream servers can
refresh them.
The refresh frequency and the refresh interval can both be configured. The template is resent when either
of the conditions is reached.