R0106-HP MSR Router Series Voice Command Reference(V7)

104
Views
POTS entity view, VoIP entity view
Predefined user roles
network-admin
Parameters
priority-order: Specifies a priority in the range of 0 to 10. The smaller the value, the higher the priority.
Usage guidelines
If a number matches multiple voice entities, the router selects the voice entity with the highest priority.
Examples
# Set the priority to 5 for POTS entity 10.
<Sysname> system-view
[Sysname] voice-setup
[Sysname-voice] dial-program
[Sysname-voice-dial] entity 10 pots
[Sysname-voice-dial-entity10] priority 5
private-line
Use private-line to configure the private line auto ring-down (PLAR) function.
Use undo private-line to disable the PLAR function.
Syntax
private-line string
undo private-line
Default
The PLAR function is disabled.
Views
FXS interface view, FXO interface view, E&M interface view
Predefined user roles
network-admin
Parameters
string: Specifies the called number, which is a string of 1 to 31 characters that can include digits 0
through 9, asterisk (*), and pound sign (#).
Usage guidelines
The PLAR function enables the subscriber line to automatically call the specified called number when the
phone goes off-hook.
Examples
# Enable PLAR for the called number 1000.
<Sysname> system-view
[Sysname] subscriber-line2/1/1
[Sysname-subscriber-line2/1/1] private-line 1000