R0106-HP MSR Router Series Voice Command Reference(V7)
41
1: Sets the output gain of the SLIC chip to 2.1 dB.
Examples
# Set the output gain of the SLIC chip to 1 (2.1 dB) for E&M interface 2/3/1.
<Sysname> system-view
[Sysname] subscriber-line 2/3/1
[Sysname-subscriber-line2/3/1] slic-gain 1
subscriber-line
Use subscriber-line to enter voice interface view.
Syntax
subscriber-line line-number
Views
System view
Predefined user roles
network-admin
Parameters
line-number: Voice interface number.
Examples
# Enter the view of FXS interface 2/1/1.
<Sysname> system-view
[Sysname] subscriber-line 2/1/1
[Sysname-subscriber-line2/1/1]
timer dial-interval
Use timer dial-interval to configure the maximum interval for dialing the next digit.
Use undo timer dial-interval to restore the default.
Syntax
timer dial-interval seconds
undo timer dial-interval
Default
The maximum interval for dialing the next digit is 10 seconds.
Views
FXS interface view, FXO interface view, E&M interface view
Predefined user roles
network-admin
Parameters
seconds: Specifies the maximum interval for dialing the next digit, in the range of 1 to 300 seconds.