R0106-HP MSR Router Series Voice Command Reference(V7)

47
3: Specifies E&M signal type III.
5: Specifies E&M signal type V.
Usage guidelines
You must configure the same E&M signal type on the originating and terminating devices.
Examples
# Configure the signal type as 3 for E&M interface 2/3/1.
<Sysname> system-view
[Sysname] subscriber-line 2/3/1
[Sysname-subscriber-line2/3/1] type 3
Digital voice interface commands
ani
Use ani to configure the terminating side to request calling information (calling category and calling
number) from the originating side.
Use undo ani to restore the default.
Syntax
ani { all | ka }
undo ani
Default
The terminating side does not request calling information from the originating side.
Views
R2 CAS view
Predefined user roles
network-admin
Parameters
all: Configures the terminating side to request the calling category and calling number.
ka: Configures the terminating side to request only the calling category.
Examples
# Configure the terminating side to request the calling category and calling number.
<Sysname> system-view
[Sysname] controller e1 2/4/1
[Sysname-E1 2/4/1] timeslot-set 0 timeslot-list 1-31 signal r2
[Sysname-E1 2/4/1] cas 0
[Sysname-cas 2/4/1:0] ani all
Related commands
ani-digit