[Sysname] controller e1 2/4/1
[Sysname-E1 2/4/1] timeslot-set 0 timeslot-list 1-31 signal r2
[Sysname-E1 2/4/1] cas 0
[Sysname-cas 2/4/1:0] timer ringback 10000
timer dl
Use timer dl to set the timeout time of line signals.
Use undo timer dl to restore the default.
Syntax
timer dl { answer | clear-back | clear-forward | | re-answer | release-guard | seizing } time
undo timer dl { answer | clear-back | clear-forward | | re-answer | release-guard | seizing }
Default
The timeout time is:
• 60000 milliseconds for answer signals.
• 10000 milliseconds for clear-back, clear-forward, and release-guard signals.
• 1000 milliseconds for seizure and reanswer signals.
Views
R2 CAS view
Predefined user roles
network-admin
Parameters
answer time: Specifies the timeout time for waiting for an answer signal, in the range of 100 to 120000
milliseconds.
This option applies to the terminating side and originating side:
• The terminating side starts this timer after sending a seizure acknowledgement signal. If it does not
send an answer signal to the originating side before the timer expires, the terminating side clears
the connection.
• The originating side starts this timer after receiving a seizure acknowledgement signal. If it does not
receive the answer signal from the terminating side before the timer expires, the originating side
clears the connection.
clear-back time: Specifies the timeout time of clear-back signals, in the range of 100 to 60000
milliseconds. The terminating side starts this timer after sending a clear-back signal. If it does not receive
a forward signal from the originating side before the timer expires, it clears the connection. This option
applies to the terminating side.
clear-forward time: Specifies the timeout time of clear-forward signals, in the range of 100 to 60000
milliseconds. The originating side starts this timer after sending a clear-forward signal. If it does not
receive a line signal (for example, clear-back or release guard signal) from the terminating side before
the timer expires, it clears the connection. This option applies to the originating side.
re-answer time: Specifies the timeout time of reanswer signals, in the range of 100 to 60000
milliseconds. The originating side starts this timer after receiving a clear-back signal from the terminating
side. If it does not receive a reanswer signal from the terminating side before the timer expires, it clears