R0106-HP MSR Router Series Voice Command Reference(V7)

72
Default
The duration is 150 milliseconds.
Views
R2 CAS view
Predefined user roles
network-admin
Parameters
time: Specifies the duration of register pulse signals, in the range of 50 to 3000 milliseconds.
Examples
# Configure the duration of register pulse signals as 300 milliseconds.
<Sysname> system-view
[Sysname] controller e1 2/4/1
[Sysname-E1 2/4/1] timeslot-set 0 timeslot-list 1-31 signal r2
[Sysname-E1 2/4/1] cas 0
[Sysname-cas 2/4/1:0] timer register-pulse 300
timeslot-set
Use timeslot-set to create a timeslot set.
Use undo timeslot-set to delete a timeslot set.
Syntax
timeslot-set ts-set-number timeslot-list timeslots-list signal r2
undo timeslot-set ts-set-number
Default
No timeslot set is created.
Views
E1 interface view, T1 interface view
Predefined user roles
network-admin
Parameters
ts-set-number: Specifies the number of a timeslot set, in the range of 0 to 30.
timeslots-list: Specifies a timeslot list. Timeslots are numbered 1 through 31 for an E1 interface and 1
through 24 for a T1 interface. The timeslot list can contain one or more individual timeslots separated by
commas (for example, 1 or 1, 2, 4), a timeslot range (for example, 5-10), or a combination of the two
forms (for example, 1-14, 15, 17-31).
signal: Specifies the signaling mode for the timeslot set.
r2: R2 signaling.
Usage guidelines
You must create a timeslot set before you can use the subscriber-line command to enter digital voice