R0106-HP MSR Router Series Voice Configuration Guide(V7)

12
Ste
Command
Remarks
4. Enable the PLAR function.
private-line string
By default, the PLAR function is
disabled.
For more information about this
command, see Voice Command
Reference.
5. Configure the interval
between on-hook and
off-hook.
timer hookoff-interval milliseconds The default is 500 milliseconds.
Configuring an E&M interface
Configuring the cable type
You must configure the same cable type for the E&M interfaces on the originating and terminating
devices. Otherwise, only one-way voice communication can be implemented.
To configure the cable type for an E&M interface:
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter E&M interface view.
subscriber-line line-number N/A
3. Configure the cable type for
the E&M interface.
cable { 2-wire | 4-wire } The default is 4-wire.
Configuring the signal type
You must configure the same signal type on the originating and terminating devices.
To configure the signal type for an E&M interface:
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter E&M interface view.
subscriber-line line-number N/A
3. Configure a signal type for the
E&M interface.
type { 1 | 2 | 3 | 5 }
The default is 5 (corresponding V
type signal).
Configuring a start mode for E&M signaling
Three start modes are available for E&M signaling:
Immediate start—After off-hook, the originating side waits for a specified period of time to send the
called number to the terminating side. During this period of time, the originating side does not
check whether the terminating side is ready to receive the called number. The terminating side
enters off-hook state after receiving the called number.