R0106-HP MSR Router Series Voice Configuration Guide(V7)

15
Configuring E&M non-signaling mode
The E&M non-signaling mode is applied when the E&M interface of the peer device does not provide the
M line and E line. In this mode, the E&M interface communicates with the peer device without signaling.
You can configure the PLAR function by using the private-line command to form a three-segment E&M
virtual private line (E&M-VoIP-E&M). When a subscriber picks up the phone, the originating device
directly dials the number specified by using the private-line command.
To configure E&M non-signaling mode:
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter voice interface view.
subscriber-line line-number N/A
3. Configure the immediate start mode
for the E&M interface.
signal immediate
The default is the immediate start
mode.
4. Enable E&M non-signaling mode.
open-trunk { caller [ monitor
interval ] | called }
By default, E&M non-signaling
mode is disabled.
Configure the open-trunk caller
[ monitor interval ] command on
the originating device, and
configure the open-trunk called
command on the terminating
device.
5. Enable the PLAR function.
private-line string
Use this command on the
originating device.
For more information about the
PLAR function, see "Configuring
dial programs."
Enabling E&M control signals pass-through
This feature operates only when the E&M non-signaling mode is enabled. As shown in Figure 6, an E&M
virtual private line is set up between the tone generator and the radio. Enable E&M control signals
pass-through for Router A and Router B so that they can send seize and idle signals for the E&M virtual
line over the IP network.
Figure 6 E&M analog control signals pass-through
To enable E&M control signals pass-through:
Step Command Remarks
1. Enter system view.
system-view N/A
2. Enter voice interface view.
subscriber-line line-number N/A