HP B-series 16Gb FC Switches Hardware Reference Guide

Power supply specifications
The power supplies are universal and operate worldwide without voltage jumpers or switches.
They meet IEC 61000-4-5 surge voltage requirements and support autoranging to accommodate
input voltages and line frequencies. Each power supply has built-in fans for cooling.
Table 16 HP StoreFabric SN6500B 16Gb FC Switch power supply specifications
ValuesSpecification
Range: 90–264 VAC Auto-volt, Nominal: 100–240 VAC, 12.0-5.0 A; 47-63
Hz
Input voltage
switch autosenses input voltage
Startup: 80–87 VAC; Turn-off: 85–75 VAC
Range: 47–63 Hz; Nominal: 50–60 HzInput frequency
Maximum of 40 A peak at 240 VAC during cold startup at 25ºC ambientInrush current
Both AC lines are fusedInput line protection
1,080 W at 12 VDCMaximum power supply output (each)
Table 17 HP SN6000B 16Gb FC Switch power supply specifications
ValuesSpecification
Range: 85–264 VAC Auto-volt, Nominal: 100–240 VAC, 2.0 A, 47–63
Hz; switch autosenses input voltage
Input voltage
Range: 47–63 Hz; Nominal: 50–60 HzInput frequency
Maximum of 50 A peak at 240 VAC for any initial current surge or spike of
10 ms or less at cold startup. Additional inrush current surges or spikes in
Inrush current
the form of AC cycles, or multiple AC cycles greater than 10 ms and less
than 150 ms, must not exceed 15 A peak.
150 W at 12 VDCSingle power supply output
12.5 A at 12 VDCMaximum current
Both AC lines are fusedInput line protection
110 W with all 48 ports populated with 16 Gb/s SWL optical mediaSystem power consumption
72 W with empty chassis and no optical media
Table 18 HP SN3000B 16Gb FC Switch power supply specifications
ValuesSpecification
Range: 85–264 VAC, nominal: 100–240 VACInput voltage
Range: 47–63 Hz; Nominal: 50–60 HzInput frequency
Maximum of 35 A peak at 240 VAC for 10 ms or lessInrush current
150 W at 12 VDCSingle power supply output
AC lines are fusedInput line protection
80 W with all 24 ports populated with 16 Gb/s SWL optical mediaSystem power consumption
60 W with empty chassis and no optical media
Environmental requirements
Table 20 (page 67) lists the acceptable environmental ranges for both operating and nonoperating
(such as during transportation or storage) conditions.
66 Specifications