HP StorageWorks Fabric OS 5.3.0a release notes (AA-RWEYE-TE, September 2007)

Fabric OS 5.3.0a
xes
Table 4 lists defects closed in this Fabric OS 5.3.0a rmware release.
Table 4 Fabric OS 5.3.0a closed defects
Closed defect su
mmary
Solution
Iswitchd pan ic occurred when doing data migration using DMM
when invalid frame issued to the switch.
Fixed per Fabric OS 5.3.0a.
Diag failure caused FA4-18 to report a fault after continuously
running CP failover test.
Fixed per Fabric OS 5.3.0a.
Panic occurred on SAN Director 2/128 when running MS commands
GPT/GPPN/GPS
/GAPNL continuously.
Fixed per Fabr
ic OS 5.3.0a.
Frame redirect: attempting to remove non-existent FR zone with NSCL
intermittently succeeded instead of giving proper error code.
Fixed per Fabric OS 5.3.0a.
When 4/64 SAN Switch is constantly rebooted, the Name server
crashed in rare conditions.
Fixed per Fabric OS 5.3.0a.
4/32B SAN Swi
tch running 5.3.0 rejected GID_Ft command from
an HBA with
FC4-type not registered” error. HBA sees no devices.
Fixed in Fabric OS 5.3.0a by
implementing a more robust zone
name check t
oavoidconfusing
frame redirection zones with regular
zone names.
In isolated cases, degraded performance can occur with the Brocade
4Gb SAN Switch for HP c-Class BladeSystem when internal por ts
are operated at 4Gb/sec.
Fabric OS 5.3.0a optimizes certain
settings in the switch to address this
issue.
Unable to congure FCIP tunnels using Web Tools in FOS 5.3.0.
FCIP wizard a nd stand-alone tab
support added for near end tunnel
conguration with Fabric OS 5.3.0a.
In frame redirect mode, GA_NXT query from initiator returns VI PID
and PWWN instead of host PWWN.
Fixed pe
r Fabric OS 5.3.0a.
HP StorageWorks Fabric OS 5.3.0a release notes
23