HP StorageWorks SAN Director Installation Guide (A7393-90009, May 2007)
Replacing the chassis174
d. Organize the cables as required. To use the cable management pillars, insert the cables into
the holes in the pillars, using a separate hole for each cable. The cables can be routed to
either side of the management comb or down through the holes in the comb.
Verify correct configuration of fabric
Copying the command outputs from this section into a file is recommended.
To verify correct configuration of the fabric:
1. Create an “after” SAN profile by entering the following commands and copying the output to a
text file named “SANafter.txt”:
• nsShow
• nsAllShow
• switchShow
• fabricShow
2. Determine any differences between the information in the “SANafter.txt” file and the information
in the “SANbefor.txt” file created earlier. In particular, look for differences in the following:
•Device types
• Number of devices
• ISL and port states
• Number of switches in the fabric
swDir:admin> nsshow
Type Pid COS PortName NodeName TTL(sec)
N 020f00; 3;10:00:00:01:73:00:29:46;10:00:00:01:73:00:29:46; na
Fabric Port Name: 20:0f:00:60:69:90:03:f0
<output truncated>
swDir:admin> nsallshow
{
020f00 021fda 021fdc 021fe0 021fe1
5 Nx_Ports in the Fabric}
swDir:admin> switchshow
switchName: swDir
<output truncated>
swDir:admin> fabricshow
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
<output truncated>
swDir:admin>