HP StorageWorks SAN Director Installation Guide (A7393-90009, May 2007)
SAN Director installation guide 181
3. Launch the terminal emulator application and configure as described below. See Table 44.
4. Follow the instructions from the modem manufacturer to set up and verify modem operation.
Verifying the modem connection
This section provides information about how to verify that the modems are correctly connected.
NOTE: This procedure requires either a telco system to dial in to the modems or a terminal
emulation program on a laptop or workstation that has an attached modem. Refer to ”Setting up a
remote modem system” on page 180 for instructions on setting up a remote modem with a terminal
emulation program.
To verify the modem connection:
1. Verify that both modem cables are firmly connected.
2. Power on the modems, if not already on.
Table 44 Terminal emulator parameters for most Windows systems
Parameter Value
Port speed (bits per second) 115200
The port usually defaults to highest speed
supported by modem; might negotiate for
slower speed.
Data protocol Standard EC
Compression Enabled
Flow control Hardware
Databits 8
Parity None
Stop bits 1
Modulation Standard