Brocade Fabric OS Command Reference Manual Supporting Fabric OS v7.0.0 (April 2011)

Fabric OS Command Reference 691
53-1001764-01
portCfgShow
22
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
LOS TOV enable OFF
NPIV capability ON
QOS E_Port AE
Port Auto Disable: OFF
Rate Limit OFF
EX Port ON
Mirror Port OFF
Credit Recovery ON
F_Port Buffers OFF
NPIV PP Limit: 126
CSCTL mode: OFF
Fault Delay 1(1.2sec)
FEC active
To display FCIP tunnels configured on a Brocade FR4-18i FC (refer to the portCfg help page for an
explanation of the displayed parameters):
switch:admin> portcfgshow 12/ge0
Mode: FCIP
Persistent Disable: OFF
Ipif configuration:
Interface IP Address NetMask MTU
----------------------------------------------------------
0 192.168.100.50 255.255.255.0 1500
1 192.168.100.51 255.255.255.0 1500
2 192.168.100.52 255.255.255.0 1500
3 192.168.100.53 255.255.255.0 1500
4 192.168.100.54 255.255.255.0 1500
5 192.168.100.55 255.255.255.0 1500
6 192.168.100.56 255.255.255.0 1500
7 192.168.100.57 255.255.255.0 1500
Arp configuration:
IP Address Mac Address
------------------------------
Iproute Configuration:
IP Address Mask Gateway Metric
------------------------------------------------------
IPv6 Address Len Gateway
Metric
-------------------------------------------------------
Fciptunnel configuration:
IPV4 FCIP TUNNEL(S)
-------------------------------------------
Tunnel ID 0
Remote IP Addr 192.168.100.40
Local IP Addr 192.168.100.50
Remote WWN Not Configured
Local WWN 10:00:00:05:1e:40:68:78
Compression off