HP DC SAN Backbone Director Switch Hardware Reference Guide (5697-2158, August 2012)

Primary partition: v6.0.0
Secondary Partition: v6.0.0
Remote CP (Slot 6, CP0): Standby
Primary partition: v6.0.0
Secondary Partition: v6.0.0
Note: If Local CP and Remote CP have different versions
of firmware, please retry firmwaredownload command.
swDir:admin>
6. If the firmware version on the replacement blade does not match that on the active CP blade,
bring the replacement blade to the same firmware level as the active blade.
7. Enter the firmwareDownload -s command to download the firmware to one of the CP
blades. Enter all requested information (use default values):
swDir:admin> firmwaredownload -s
Server Name or IP Address: 192.168.100.1
User Name: user
File Name: /software/v6.0.0/release.plist
Password: ********
Do Auto-Commit after Reboot [Y]:
Reboot system after download [N]:
Firmwaredownload has started.
2007/07/03-14:59:21, [SULB-1001], 923,,
WARNING, DC Director, Firmwaredownload command has started.
Start to install packages......
dir ##################################################
ldconfig ##################################################
glibc ##################################################
bash ##################################################
readline ##################################################
terminfo ##################################################
termcap ##################################################
setup ##################################################
<output truncated>
tz ##################################################
mtracer-tool ##################################################
lkcd ##################################################
sysstat ##################################################
Removing unneeded files, please wait ...
Finished removing unneeded files.
All packages have been downloaded successfully.
Firmwaredownload has completed successfully.
2007/07/03-15:05:56, [SULB-1002], 924,, INFO, DC Director,
Firmwaredownload command has completed successfully.
8. Enter the firmwareDownloadStatus command to verify that the firmware has been updated.
9. Enter the haEnable command to re-enable HA on the active CP blade.
10. Enter the reboot command.
11. Verify that the reboot is complete and the CP blades have achieved failover redundancy:
a. Wait until the status LEDs on both CP blades are not lit.
b. Enter the haShow command, and verify that the command output includes HA Enabled
Heartbeat Up. If not, re-enter the command until you have verified that redundancy is
achieved.
12. Enter the firmwareShow command to verify that the firmware version has been updated.
13. Pack the faulty CP blade in the packaging provided with the new CP blade, and contact HP
for the procedure for returning the faulty blade.
14. Replace the chassis door. See Installing the chassis door (page 62).
72 Replacing DC SAN Director FRUs